General Insulation & Bill Savings

A quick way to check is looking at your exterior brick pattern. If all the bricks are laid lengthwise (stretchers), your home is almost certainly built with cavity walls (typical in properties built after 1930). If you see alternating long and short bricks (headers and stretchers), it is a solid 9-inch brick wall. Furthermore, measuring door/window reveal depth: solid walls are usually under 260mm thick, whereas cavity walls are 300mm+. Our free survey confirms this precisely.
Yes! Black mould is caused when warm moisture-laden indoor air touches cold uninsulated exterior masonry, condensing into liquid droplets. By wrapping your walls with continuous insulation (EWI or IWI), the internal wall surface temperature increases to match room temperature, removing the dew point. Mould simply cannot germinate on a warm, dry wall.
External or internal wall insulation typically increases an EPC rating by 15 to 25 Standard Assessment Procedure (SAP) points. This frequently elevates an uninsulated home from EPC Band E or F into Band C or high Band B, fulfilling proposed UK minimum landlord standards and increasing property resale value.

Solar PV, Battery Storage & Heat Pumps

Combining rooftop solar PV with a home battery allows you to use up to 80%–85% of your generated clean energy on-site instead of exporting it cheaply. Furthermore, with smart off-peak tariffs (e.g. charging your battery at 7p/kWh overnight), typical family homes reduce grid electricity expenses by £600 to £1,200+ annually.
The UK Government Boiler Upgrade Scheme provides a direct £7,500 non-repayable grant for homeowners replacing a fossil fuel boiler (gas, oil, or LPG) with an MCS-certified Air Source Heat Pump. Ember Efficiency handles the Ofgem application and voucher redemption on your behalf, deducting the £7,500 directly off your invoice quotation.
Yes! Standalone battery storage systems can be charged from the grid during off-peak overnight hours (such as Octopus Go / Agile night windows) and discharged during peak daytime and evening hours, delivering substantial electricity savings even without solar panels.

External Wall Insulation (EWI)

In England and Wales, EWI usually falls under Permitted Development rights provided the property is not a Listed Building, situated in an Article 4 Conservation Area, or within a National Park. We check your local planning authority records during our survey.
To achieve the Part L Building Regulations target U-value of 0.26 W/m²K or better, our systems typically use 90mm to 110mm of grey EPS insulation, plus approximately 8mm to 10mm of basecoat and silicone render finish. If boundary lines are tight, we can use ultra-thin 60mm phenolic boards (Kingspan K5).
No! Our silicone renders are "through-coloured", meaning the pigment is mixed entirely throughout the render matrix. There is no surface paint film to peel, flake, or blister. They are self-cleaning and hydrophobic, requiring only an occasional light hose down to keep them pristine.

Internal Wall Insulation (IWI)

Yes, this is one of the main advantages of IWI. You can insulate your north-facing bedrooms, living rooms, or specific exterior walls room-by-room to fit around your family's decorating timetable and budget.
Yes. During installation, simply inform our carpenters where you intend to mount flat-screen televisions, heavy mirrors, or kitchen units. We install 18mm structural timber backing ply (patressing) behind the plasterboard, allowing you to anchor heavy items with standard wood screws.

Loft & Attic Insulation

Current UK Building Regulations (Part L) mandate a target U-value of 0.16 W/m²K for horizontal ceilings under an unheated roof space. Achieving this performance requires a minimum of 270mm of standard mineral wool quilt. Ember Efficiency specifies 300mm (100mm base layer + 200mm cross-layer) to exceed regulations and eliminate heat loss through ceiling joists.
Yes. We install certified Euroclass A1 Non-Combustible rock and glass mineral wool. It does not ignite, support flame spread, or emit toxic fumes, providing an additional fire barrier between your roof timbers and living spaces.

Grants & Guarantees

Our external wall insulation systems are backed by an independent, insurance-backed 25-year structural warranty (such as GDGC or SWIGA accredited schemes). This policy is legally tied to your property address and remains valid even if you sell the house, providing complete confidence for future mortgage surveyors.
Homeowners and private tenants with EPC bands D, E, F, or G may qualify for full or partial funding under the UK Government's ECO4 or Great British Insulation Scheme (GBIS) if they receive certain income-related benefits or meet Local Authority Flexible Eligibility (LA Flex) criteria. Contact Deepak and the Ember team with your postcode, and we will verify your eligibility on the national database.

Have a Question Not Listed Here?

Our certified retrofit specialists are happy to answer any technical questions regarding your property's specific construction.

Free Property Diagnostics

Ready To Get Clear Advice On Your Home?

Book your complimentary thermal assessment and itemised proposal with no obligation.

Direct line: +44 7515 553651
Call Now